Medical Environmental Monitoring



Laboratory Formaldehyde Monitoring

  • Monitoring of breathing zones for employee exposure
  • Testing available for Xylene, Alcohol, Toluene, and others
  • Testing areas include: Pathology Grossing, Histology, Morgue, Microbiology, Cytology, OR, OB, and Dialysis
  • Results include: 8 HR TWA, 15 MIN STEL
  • Ventilation System Evaluation of inlet and exhaust vents to Calculate
    Total Air Exchange Rate
  • Passive Dosimeter Badge Order Form


Ethylene Oxide Monitoring

  • Environmental monitoring of breathing zones for employee exposure
  • Monitoring during running of sterilizers and aerators
  • Results include: 8 HR TWA, 15 MIN STEL
  • Leak detection of Sterilizer, Aerator, and Supply Lines and Tanks
  • Ventilation System Evaluation of inlet and exhaust vents to Calculate
    Total Air Exchange Rate
  • Passive Dosimeter Badge Order Form


Waste Anesthetic Gas Monitoring

  • Monitoring for employee exposure to N2O and Halogenated agents in the OR's, Delivery, Cysto, Endo, and Recovery Rooms
  • Leak detection is performed on the anesthesia machines, all connections of supply hoses, and N2O supply manifold
  • Testing includes checking vacuum inlets for pressure and flow
  • Ventilation System Evaluation of inlet and exhaust vents to Calculate
    Total Air Exchange Rate
  • Passive Dosimeter Badge Order Form


Glutaraldehyde Monitoring

  • Monitoring breathing zones for employee exposure during peak usage with digital electrochemical sensor for accurate instantaneous results (OSHA Approved Method)
  • Ceiling Limit is 0.2 PPM (Set by ACGIH)
  • To Calculate Total Air Exchange
  • Testing Areas include: OR, CS Endo, Cysto, RT, ER, and Anesthesia
  • Ventilation System Evaluation of inlet and exhaust vents to Calculate
    Total Air Exchange Rate
  • Passive Dosimeter Badge Order Form


Anesthesia Vaporizer Accuracy

  • Accuracy verification for calibration of vaporizers within manufacturer's standard of plus or minus 15% tolerance range
  • Documentation of Brand, Model, Serial Number, Machine Serial Number, and Halogenated agents used
  • Results are on-site


Isolation Room Ventilation Evaluation

  • Evaluation / Inspection of intake and exhaust venting performance
  • Calculate Total Air Exchange Rate
  • Negative / Positive Pressure Check for air movement
  • Evaluate exhaust termination point
  • Evaluate employee respiratory protection plan


Indoor Air Quality Monitoring

  • Infrared gaseous contaminant testing
  • Volatile and Semi-Volatile Organic compound testing
  • Microbiological contaminant testing
  • Airborne particulate testing
  • Comprehensive Ventilation Evaluation
  • Passive Dosimeter Badge Order Form


Features of NMC's Environmental Monitoring Services

  • Evaluations and Recommendations for Employee Work Practices and Emergency Action Plans for all services
  • Testing complies with applicable regulations set by JCAHO, OSHA, DHHS, NIOSH, ACGIH, NFPA, CGA, and ANSI(*)
  • State of the Art technological testing equipment and testing procedures
  • Eight (8) Service technicians with 90+ years of combined experience
  • OSHA method trained staff
  • Guaranteed customer satisfaction for services performed
  • One million dollar professional liability insurance
  • Representation if cited by OSHA


Download a copy of the Medical Gas and Environmental Monitoring Bid Sheet